Showing 1–12 of 43 results

Show sidebar
Close

VKLP/D 3/4” – 1” – 1”1/4 – 1”1/2 – 2” gas

3-way diverter valve sleeve connection piston operated Piloted solenoid valve, with ø51 - ø64 1“1/2 - ø76 2” piston, designed for air, inert gases, water, refrigerants, diesel and very dense oils. It can be mounted either vertically or horizontally. The coil is 360° rotatable. The 3-way diverter valve diverts the air passage energizing the coil, while the return is regulated by a spring. Led equipped male and female connectors included. Download the card
Close

VKLP/85 3/4” – 1” – 1”1/4 gas

2-way N.C. sleeve connection piston operated Piloted solenoid valve, with ø64 piston, designed for air, inert gases, water, refrigerants, diesel and very dense oils. The big-bore piston ensures better safety at high pressure, even with low pilot pressure. It can be mounted either vertically or horizontally. The coil is 360° rotatable. The N.C. (Normally Closed) 2-way valve allows the supply air to pass energizing the coil, while the closure is regulated by a spring. Led equipped male and female connectors included. Download the card
Close

GSP/AU

Suitable for pressurized tanks Protection degree: IP65 Automatic MINIMUM and MAXIMUM level regulator for fluid tanks (water, oil, fuel oil, emulsifiers, etc.). The GSP/AU regulator is watertight therefore it can be mounted on pressurized tanks or tanks with vapors. The electrical and mechanical parts of the regulator are not in contact with the interior of the tank. Electrically operated with mercury bulb mounted on anti- shock rubber. Connector MPM 183 PG09. To be vertically installed via flange. Stem length: MIN 200 – MAX 1200 mm. All external and internal brass parts are nickel-plated, the aluminium and steel parts are epoxy coated to ensure corrosion resistance. Download the card
Close

GSP/CAU

With barrel Suitable for pressurized tanks Protection degree: IP65 Automatic MINIMUM and MAXIMUM level regulator for fluid tanks (water, oil, fuel oil, emulsifiers, etc.). The GSP/CAU regulator is watertight therefore it can be mounted on pressurized tanks or tanks with vapors. The electrical and mechanical parts of the regulator are not in contact with the interior of the tank. Electrically operated with mercury bulb mounted on anti- shock rubber. Connector MPM 183 PG09. To be vertically installed via threaded connections. Centre-to-centre distance MIN 200 MAX 1500 mm. All external and internal brass parts are nickel-plated, the aluminium and steel parts are epoxy coated to ensure corrosion resistance. Download the card
Close

IGP

Protection degree: IP40 Electrically operated MINIMUM and MAXIMUM level switch for fluid tanks (water, oil, fuel oil, emulsifiers, etc.) with microswitch. Connector MPM 183 PG09. To be vertically installed via flange. Stem length: MIN 200 – MAX 1200 mm. All external and internal brass parts are nickel-plated, the steel parts are epoxy coated to ensure corrosion resistance. Download the card
Close

ILM

With decompression pump Protection degree: IP65 This device is suitable for the level measurement of liquids in a tank (paints, fuel oil, solvents, water). Composed of phosphor bronze capsule manometer with aluminium case, chrome brass pressure pump and stainless steel rod. To be vertically installed at the top edge of the tank via male fitting 1“ gas. Mode of operation: activate the pump manually after the installation. By doing this, the stem will be emptied and the manometer will be pressurized depending on the stem length and the specific weight of the liquid, indicating the liquid level in the tank. If the level drops, the pressure on the manometer will diminish and, as a result, the dial hand will drop. To ensure a precise reading it is advisable to pump air into the tube at every tank refill. Apart from the stem length it is necessary to indicate the specific weight of the liquid to be measured. If this information is missing the instrument will be calibrated at specific weight 1. Download the card
Close

ILS

Protection degree: IP64 Automatic MINIMUM and MAXIMUM level regulator for fluid tanks (water, oil, fuel oil, emulsifiers, etc.). The electrical and mechanical parts of the regulator are not in contact with the interior of the tank. Electrically operated with microswitch, nickel-plated brass cable gland connection. Rope length MIN 300 MAX 10000 mm. All external and internal brass parts are nickel-plated, the aluminium and steel parts are epoxy coated to ensure corrosion resistance. Download the card
Close

KG – KGS – KGB

Type approval: R.I.NA Automatic pressure regulator for air, water, oil, diesel, emulsifiers, etc. Electrically operated with microswitch, brass cable gland connection. Type KG is ideal for alternating current max 250VAc 10A. Type KGB is bipolar with the same electrical features as type KG. Type KGS has a magnetic blowout and it is ideal for direct current max 125VDc or 250VDc 3A. The installation can be either vertical or horizontal via male 1/4” threaded connection or female NPT 1/4” on request. All the steel parts are nickel-plated, the aluminium parts are epoxy coated to ensure corrosion resistance. Download the card
Close

KTS

With capillary Protection degree: IP40 Automatic maximum and minimum temperature regulator. The KTS thermostat is a capillary type with liquid filled shank, it has a visible thermometric scale that can be adjusted only internally. Regulation range on numerical scale (15-95, 40-120, 80-160, 110-190, 150-230°C.) Thermal differential ±5°C. capillary length 1.500 mm Pocket length mm. from 100 to 1500 (D) Compliant with C.E.I. standards. Download the card
Close

RLV.P.Q

With Proximity sensors and protection Automatic MINIMUM and MAXIMUM (and intermediate if applicable) level regulator with visual indicator and millimeter scale for fluid tanks (water, oil, fuel oil, emulsifiers, etc.). The RLV.P-Q regulator is to be vertically installed on the top part of the vat or tank. Electrically operated with adjustable proximity sensors mounted on the aluminium guide tube via proximity port (optional). Stem length MIN 200 MAX 1200 mm. Visual part length MIN 100 MAX 800 mm. Download the card
Close

RLVL.R

With magnetic REED switches and LEXAN sight tube Protection degree: IP40 Automatic MINIMUM and MAXIMUM level regulator with visual indicator for fluid tanks (water, oil, fuel oil, emulsifiers, etc.). The RLV.L.R regulator is watertight therefore it can be mounted on pressurized tanks or tanks with vapors. Electrically operated with magnetic REED switches placeable on the sight tube via clamp MPM-DXF30. Connector linkage. To be vertically installed via flange. Stem length: MIN 200 – MAX 1200 mm. Sight tube length: MIN 100 MAX 800 mm. All the steel parts are nickel-plated. Download the card
Close

TDP/X – TDI/X – TDR/X

Mercury or inert gas expansion Protection degree: IP65 Device suitable for measuring temperature ranges from -40 to +600°C, with variance ±1% FS. The dial is made of white coated aluminium, with graduated scale and indelible black signs to facilitate the reading. With diameters: 80 – 100 – 150 – 200 – 250mm. Burnished steel scale with micrometric regulation. The transparent window is made of glass. Capillary, bulb and pocket are made of stainless steel. The length is decided according to the customer’s request. Upon demand, electrical contacts can be included. There can be different types of contacts: unipolar, bipolar or bipolar with independent circuit, minimum and maximum. The contacts are made of pure silver or, upon request, platinum. Download the card